Analysis of the Influence of Hydraulic and Hydrological Factors on the Operating Conditions of a Small Hydropower Station on the Example of the Stary Młyn Barrage on the Głomia River in Poland
2023, Hammerling, Mateusz, Walczak, Natalia, Kałuża, Tomasz
The operation of water structures causes various problems. They are related, for example, to the material carried by the water, hydrological conditions, range of operation of hydroelectric turbines, or water elevations at the lower position of the hydroelectric power plant. Among the various operational problems, this article focuses mainly on the impact of the backwater of Gwda river on the water level elevations at the lower station of the Stary Młyn hydropower plant in Dobrzyca. The power plant is located on Głomia river. The analysis was carried out for different flow variants in both the Gwda and Głomia rivers. The effect of characteristic flows on the water surface level at the lower station of the hydropower plant was examined. It was found that the water surface level at the lower station of the hydropower plant is strongly influenced by flows higher than the average high flow on Gwda river. Due to the extent of the backwater in current operating conditions, the hydroelectric power plant is shut down from flows on Gwda river of 30–28 m3/s (flows that are not much higher than the multi-year average SSQ). The modeling results were confirmed by an analysis of power plant shutdowns of normal operation especially in wet years, when the plant did not operate for almost half of the year (188 days), with losses of 203 MWh. It was also shown that even a small additional damming of water, e.g., of the order of 0.2 m, can extend the operating time of a power plant up to 249 days even under unfavorable hydrological conditions. Factors related to climate change are beginning to play an increasingly important role in the current operating conditions of small lowland hydroelectric power plants. They can contribute to a reduction in electricity production. The proposed solution related to the possibility of greater water retention on dammed-up water barrages allows one to partially offset these problems as well.
Laboratory Research on Hydraulic Losses on SHP Inlet Channel Trash Racks
2022, Walczak, Natalia, Walczak, Zbigniew, Tymiński, Tomasz
There is currently a growing trend towards renewable energy sources, which are characterised by a guaranteed power supply and low failure rate. Hydropower plants (small or large) are an example of such a source. They supply a total of 16% of the world’s electricity. The advantages of a small hydropower plant include the relatively simple construction process and the lack of need for upstream water storage. SHPs are one of the most cost-effective and environmentally friendly energy technologies, which is why they are steadily increasing in popularity. One of the important components of SHPs are the trash racks in the inlet channels. Their main purpose is to catch debris and other elements carried downstream and to prevent these pollutants from reaching the turbine units. They can also protect migrating ichthyofauna such as larger fish. If trash racks are installed in the inlet channel, hydraulic losses are to be expected due to the reduction in the flow cross-section through the racks (bars) themselves and through the accumulation of debris and various types of trash on these racks. Energy losses on the trash racks affect the financial aspect of SHP investments. This paper presents the results of laboratory tests on trash racks for SHPs by taking into account the different shapes of the bars used, their number and spacing, and the angles of the trash racks to estimate the hydraulic losses on the trash racks. The measured values of hydraulic losses Δh on the trash racks varied according to the type of trash racks, the density of the bars in the cross-section, and the angle of the trash racks from the horizontal, reaching the highest values on the trash racks with angle bars (AB). They were almost eight times greater than those recorded on cylindrical-bar (CB) trash racks, although they involved different angles. It was shown that the discrepancy in the magnitude of losses on trash racks can be large, even for the same type of trash racks. It depends significantly on the design (shape and bar spacing) of the trash racks and the way the trash racks are installed. Depending on the inclination angle, the increase in energy losses reached 70% for angle bars, 60% for flat-bar trash racks, and almost 40% for cylindrical bars. The values of energy loss as well as the loss coefficient β varied non-linearly for the different bar types depending on the angle of inclination of the gratings, and the degree of this non-linearity depended on the type of bars and the blockage ratio of the section. The presented research results can be useful both during the design and the operation of an SHP.