Szanowni Państwo, w związku z bardzo dużą ilością zgłoszeń, rejestracją danych w dwóch systemach bibliograficznych, a jednocześnie zmniejszonym zespołem redakcyjnym proces rejestracji i redakcji opisów publikacji jest wydłużony. Bardzo przepraszamy za wszelkie niedogodności i dziękujemy za Państwa wyrozumiałość.
Repository logoRepository logoRepository logoRepository logo
Repository logoRepository logoRepository logoRepository logo
  • Communities & Collections
  • Research Outputs
  • Employees
  • AAAHigh contrastHigh contrast
    EN PL
    • Log In
      Have you forgotten your password?
AAAHigh contrastHigh contrast
EN PL
  • Log In
    Have you forgotten your password?
  1. Home
  2. Bibliografia UPP
  3. Bibliografia UPP
  4. Application of Experimental Studies of Humidity and Temperature in the Time Domain to Determine the Physical Characteristics of a Perlite Concrete Partition
 
Full item page
Options

Application of Experimental Studies of Humidity and Temperature in the Time Domain to Determine the Physical Characteristics of a Perlite Concrete Partition

Type
Journal article
Language
English
Date issued
2024
Author
Szymczak-Graczyk, Anna 
Gajewska, Gabriela
Ksit, Barbara
Laks, Ireneusz 
Kostrzewski, Wojciech
Urbaniak, Marek 
Pawlak, Tomasz 
Faculty
Wydział Inżynierii Środowiska i Inżynierii Mechanicznej
Journal
Materials
ISSN
1996-1944
DOI
10.3390/ma17194938
Web address
https://www.mdpi.com/1996-1944/17/19/4938
Volume
17
Number
19
Pages from-to
art. 4938
Abstract (EN)
These days, the use of natural materials is required for sustainable and consequently plus-, zero- and low-energy construction. One of the main objectives of this research was to demonstrate that pelite concrete block masonry can be a structural and thermal insulation material. In order to determine the actual thermal insulation parameters of the building partition, in situ experimental research was carried out in real conditions, taking into account the temperature distribution at different heights of the partition. Empirical measurements were made at five designated heights of the partition with temperature and humidity parameters varying over time. The described experiment was intended to verify the technical parameters of perlite concrete in terms of its thermal insulation properties as a construction material used for vertical partitions. It was shown on the basis of the results obtained that the masonry made of perlite concrete blocks with dimensions of 24 × 24.5 × 37.5 cm laid on the mounting foam can be treated as a building element that meets both the structural and thermal insulation requirements of vertical single-layer partitions. However, it is important for the material to work in a dry environment, since, as shown, a wet perlite block has twice the thermal conductivity coefficient. The results of the measurements were confirmed, for they were known from the physics of buildings, the general principles of the formation of heat and the moisture flow in the analysed masonry of a perlite block. Illustrating this regularity is shown from the course of temperature and moisture in the walls. The proposed new building material is an alternative to walls with a layer of thermal insulation made of materials such as polystyrene or wool and fits into the concept of sustainable construction, acting against climate change, reducing building operating costs, improving living and working conditions as well as fulfilling international obligations regarding environmental goals.
Keywords (EN)
  • perlite concrete

  • thermal conductivity coefficient...

  • sustainable construction

  • homogeneous partitions

  • hygrothermal performance

  • humidity of perlite

  • heat transfer

  • single-layer wall