Szanowni Państwo, w związku z bardzo dużą ilością zgłoszeń, rejestracją danych w dwóch systemach bibliograficznych, a jednocześnie zmniejszonym zespołem redakcyjnym proces rejestracji i redakcji opisów publikacji jest wydłużony. Bardzo przepraszamy za wszelkie niedogodności i dziękujemy za Państwa wyrozumiałość.
Repository logoRepository logoRepository logoRepository logo
Repository logoRepository logoRepository logoRepository logo
  • Communities & Collections
  • Research Outputs
  • Employees
  • AAAHigh contrastHigh contrast
    EN PL
    • Log In
      Have you forgotten your password?
AAAHigh contrastHigh contrast
EN PL
  • Log In
    Have you forgotten your password?
  1. Home
  2. Bibliografia UPP
  3. Bibliografia UPP
  4. High throughput and automated solid-phase microextraction and determination by liquid chromatography-mass spectrometry for the analysis of mycotoxins in beer
 
Full item page
Options

High throughput and automated solid-phase microextraction and determination by liquid chromatography-mass spectrometry for the analysis of mycotoxins in beer

Type
Journal article
Language
English
Date issued
2023
Author
Zhou, Wei
Wieczorek, Martyna N. 
Pawliszyn, Janusz
Faculty
Wydział Nauk o Żywności i Żywieniu
Journal
Food Chemistry
ISSN
0308-8146
DOI
10.1016/j.foodchem.2023.136557
Volume
426
Number
15 November 2023
Pages from-to
art. 136557
Abstract (EN)
There is high demand for rapid screening of toxics in food analysis. In this study, a new high-throughput and automated solid-phase microextraction (SPME) system was employed for the sample preparation of mycotoxins in beers. Matrix compatible SPME blades with thin coating layer were used, which significantly decreased the matrix effects in beer samples (≤ 12%). This SPME system allows 96 samples to be processed automatically and simultaneously with average preparation time of 57 s per sample. After sample preparation, the 96-well plate with desorption solution was sealed with a thin film and put into the LC-MS sampler for analysis via positive/negative ESI switching mode. The results also showed good sensitivity (limits of detection between 0.02 and 3 ng/mL) with R2 ≥ 0.9971, reproducibility (intra- and inter-day ≤ 8% and ≤ 13%, respectively), and accuracy (recoveries between 79% and 121%).
Keywords (EN)
  • solid-phase microextraction

  • high-throughput

  • LC-MS

  • mycotoxin

  • automation